Review




Structured Review

Arthrex Inc sutures 2 0 fiberwire
Sutures 2 0 Fiberwire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/fiberwire/pmc12801006-15-7-8
Average 86 stars, based on 1 article reviews
sutures 2 0 fiberwire - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

Infection:

Article Title: Simultaneous Bilateral Patellar Tendon Ruptures Treated with Primary Repair and Dermal Allograft Augmentation: A Case Report
Article Snippet: The medial and lateral retinaculum were then repaired using 2-0 FiberWire (Arthrex, Naples, FL) and a defunctioning #5 FiberWire (Arthrex, Naples, FL) suture was placed in a purse string fashion around the patella and patellar tendon and then through a drill hole just distal to the tibial tubercle.

Article Title: Primary Arthroscopy-Assisted Foveal Repair of Triangular Fibrocartilage Complex Associated with Acute Distal Radius Fractures in Young Adults
Article Snippet: When complete foveal disruption (Atzei class 2) was confirmed by a positive hook test, 22 arthroscopy-assisted transosseous TFCC foveal repair was performed using a 2-0 FiberWire (Arthrex, Naples, FL; Fig. 1 ).

Article Title: How important is the teres minor in reverse total shoulder arthroplasty combined with latissimus dorsi transfer?
Article Snippet: Background: The utility of latissimus dorsi (LD) transfer combined with reverse total shoulder arthroplasty to restore external rotation (ER) strength is clinically well-established, but studies directly comparing LD and intact teres minor (TM) strength are lacking.. Also, variations in eccentricity in the glenoid components have been under-estimated.. Methods: We used 8 fresh-frozen cadaveric shoulders in this study.

Article Title: Modified Centralization Technique of Tibial Side Capsulodesis for Radial Tear of Incomplete Discoid Lateral Meniscus
Article Snippet: A reduction suture is applied using the all-inside technique with a 2-0 FiberWire and a knee Scorpion (Arthrex) ( A).

Article Title: Superior suspensory complex of the shoulder reconstruction for acute and chronic acromioclavicular joint dislocations: the Queensland Unit for Advanced Shoulder Research 3-tunnel technique
Article Snippet: The ligament ends are crisscrossed over the top of the clavicle under tension and repaired with a 2-0 FiberWire (Arthrex, Naples, FL, USA) nonabsorbable composite braided suture ( E ).

Article Title: Modified Centralization Technique of Tibial Side Capsulodesis for Radial Tear of Incomplete Discoid Lateral Meniscus
Article Snippet: The knee is positioned in a figure-4 position. (A) An all-inside suture is applied with an all-inside technique using a 2-0 FiberWire and a knee Scorpion (Arthrex; white arrow). (B) Radial tear site is tied using an inside-out repair with a bone marrow aspirate fibrin clot. (F, femoral condyle.)

Article Title: Modified Centralization Technique of Tibial Side Capsulodesis for Radial Tear of Incomplete Discoid Lateral Meniscus
Article Snippet: All-inside suture methods are applied using the all-inside technique with a 2-0 FiberWire and knee Scorpion (Arthrex).

Article Title: Combined Transosseous and Capsular Repair Improves Grip Strength in Triangular Fibrocartilage Complex Tears: A Randomized Controlled Trial.
Article Snippet: 119 Under arthroscopic guidance, a 20 G (0.9 mm outer diameter) syringe needle was used to introduce 120 a 2-0 FiberWire (Arthrex, USA), a high-strength, braided composite suture, through one of the 121 bone tunnels traversing the TFCC to access the ulnocarpal joint cavity.



Similar Products

86
Arthrex Inc sutures 2 0 fiberwire
Sutures 2 0 Fiberwire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/fiberwire/pmc12801006-15-7-8
Average 86 stars, based on 1 article reviews
sutures 2 0 fiberwire - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Arthrex Inc non-absorbable sutures 2-0 fiberwire
Non Absorbable Sutures 2 0 Fiberwire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/fiberwire+suture/pmc12272503-45-4-8
Average 90 stars, based on 1 article reviews
non-absorbable sutures 2-0 fiberwire - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Arthrex Inc 2-0 fiberwire
2 0 Fiberwire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/2+0+fiberwire/pmc12088808-17-25-26
Average 90 stars, based on 1 article reviews
2-0 fiberwire - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Arthrex Inc fiberwire no. 2-0
(A) The anchors should be positioned approximately 2 to 3 mm from the acetabular rim, with a distance of 10 to 12 mm between each anchor. (B) One tail thread (white <t>FiberWire</t> [Arthrex], indicated by the blue arrow) of the most medial anchor is passed through medial end (displayed as a circular roll) of the graft used for the fixation of the medial graft end. The red arrow indicates the medial traction suture, while the black arrow points to the lateral end’s traction suture.
Fiberwire No. 2 0, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/fiberwire/pmc12177393-38-41-42
Average 90 stars, based on 1 article reviews
fiberwire no. 2-0 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Arthrex Inc fiberwire #2-0 sutures
(A) The anchors should be positioned approximately 2 to 3 mm from the acetabular rim, with a distance of 10 to 12 mm between each anchor. (B) One tail thread (white <t>FiberWire</t> [Arthrex], indicated by the blue arrow) of the most medial anchor is passed through medial end (displayed as a circular roll) of the graft used for the fixation of the medial graft end. The red arrow indicates the medial traction suture, while the black arrow points to the lateral end’s traction suture.
Fiberwire #2 0 Sutures, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/fiberwire+suture/pm40120638-77-10-15
Average 90 stars, based on 1 article reviews
fiberwire #2-0 sutures - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Arthrex Inc 2-0 fiberwire sutures
(A) The anchors should be positioned approximately 2 to 3 mm from the acetabular rim, with a distance of 10 to 12 mm between each anchor. (B) One tail thread (white <t>FiberWire</t> [Arthrex], indicated by the blue arrow) of the most medial anchor is passed through medial end (displayed as a circular roll) of the graft used for the fixation of the medial graft end. The red arrow indicates the medial traction suture, while the black arrow points to the lateral end’s traction suture.
2 0 Fiberwire Sutures, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/fiberwire+suture/pmc11791121-29-13-15
Average 90 stars, based on 1 article reviews
2-0 fiberwire sutures - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Arthrex Inc #2-0 fiberwire
(A) The anchors should be positioned approximately 2 to 3 mm from the acetabular rim, with a distance of 10 to 12 mm between each anchor. (B) One tail thread (white <t>FiberWire</t> [Arthrex], indicated by the blue arrow) of the most medial anchor is passed through medial end (displayed as a circular roll) of the graft used for the fixation of the medial graft end. The red arrow indicates the medial traction suture, while the black arrow points to the lateral end’s traction suture.
#2 0 Fiberwire, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2-0+fiberwire/2+0+fiberwire/pmc11732250-18-32-33
Average 90 stars, based on 1 article reviews
#2-0 fiberwire - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


(A) The anchors should be positioned approximately 2 to 3 mm from the acetabular rim, with a distance of 10 to 12 mm between each anchor. (B) One tail thread (white FiberWire [Arthrex], indicated by the blue arrow) of the most medial anchor is passed through medial end (displayed as a circular roll) of the graft used for the fixation of the medial graft end. The red arrow indicates the medial traction suture, while the black arrow points to the lateral end’s traction suture.

Journal: Arthroscopy Techniques

Article Title: Concurrent Arthroscopic Revision of the Hip Labral and Anterior Capsular Reconstruction Utilizing Iliotibial Band Autograft

doi: 10.1016/j.eats.2024.103366

Figure Lengend Snippet: (A) The anchors should be positioned approximately 2 to 3 mm from the acetabular rim, with a distance of 10 to 12 mm between each anchor. (B) One tail thread (white FiberWire [Arthrex], indicated by the blue arrow) of the most medial anchor is passed through medial end (displayed as a circular roll) of the graft used for the fixation of the medial graft end. The red arrow indicates the medial traction suture, while the black arrow points to the lateral end’s traction suture.

Article Snippet: Specifically, on the acetabular side, No. 2-0 absorbable sutures are used, with 4 sutures being passed through the longer edge (matching the number of planned anchor placements), and the 2 corners on the capsular side are also sutured with No. 2-0 FiberWire (Arthrex).

Techniques:

(A) The black arrow points to the positions of the 4 anchors on the acetabular side (first at 3-o’clock, second at 2-o’clock, third at 1-o’clock, and fourth at 12-o’clock). We can see that the labral graft (yellow font) has been fixed in place. The white tail threads of all the anchors have been knotted and trimmed. We have left the blue tail threads of the first, third, and fourth screws for the corresponding graft suture replacement. (B) The red arrow indicates the 2 preplaced polydioxanone sutures within the residual joint capsule tissue. (C) The red-marked No. 2-0 absorbable sutures on the acetabular side of the graft will be used to replace the corresponding blue tail threads of the numbered anchors on the acetabulum. The 2 No. 2-0 FiberWire sutures (Arthrex) indicated by the red arrow correspond to the preplaced polydioxanone sutures, which are shown in A. (D) The graft is fed along the tail thread of the first anchor into the joint and then tied and fixed into place. (E) The completed fixation of the joint capsular graft.

Journal: Arthroscopy Techniques

Article Title: Concurrent Arthroscopic Revision of the Hip Labral and Anterior Capsular Reconstruction Utilizing Iliotibial Band Autograft

doi: 10.1016/j.eats.2024.103366

Figure Lengend Snippet: (A) The black arrow points to the positions of the 4 anchors on the acetabular side (first at 3-o’clock, second at 2-o’clock, third at 1-o’clock, and fourth at 12-o’clock). We can see that the labral graft (yellow font) has been fixed in place. The white tail threads of all the anchors have been knotted and trimmed. We have left the blue tail threads of the first, third, and fourth screws for the corresponding graft suture replacement. (B) The red arrow indicates the 2 preplaced polydioxanone sutures within the residual joint capsule tissue. (C) The red-marked No. 2-0 absorbable sutures on the acetabular side of the graft will be used to replace the corresponding blue tail threads of the numbered anchors on the acetabulum. The 2 No. 2-0 FiberWire sutures (Arthrex) indicated by the red arrow correspond to the preplaced polydioxanone sutures, which are shown in A. (D) The graft is fed along the tail thread of the first anchor into the joint and then tied and fixed into place. (E) The completed fixation of the joint capsular graft.

Article Snippet: Specifically, on the acetabular side, No. 2-0 absorbable sutures are used, with 4 sutures being passed through the longer edge (matching the number of planned anchor placements), and the 2 corners on the capsular side are also sutured with No. 2-0 FiberWire (Arthrex).

Techniques: